Water Factory Systems N4000 Series Instrukcja Obsługi

Przeglądaj online lub pobierz Instrukcja Obsługi dla Detektory tlenku węgla (CO) Water Factory Systems N4000 Series. Water Factory Systems N4000 Series Instruction manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
120-00004 REV A 10/06/2011 4000 DIGITAL MANUAL PAGE 1
Instruction Manual
4000 Series Digital Portable Analyzer
Service Department
(800) 458-6153 ext. 121
(818) 882-2331 ext. 121
FAX (818) 341-0642 E-mail: service@gasdetection.com
Przeglądanie stron 0
1 2 3 4 5 6 ... 28 29

Podsumowanie treści

Strona 1 - Instruction Manual

120-00004 REV A 10/06/2011 4000 DIGITAL MANUAL PAGE 1 Instruction Manual 4000 Series Digi

Strona 2 - TABLE OF CONTENTS

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 10 2.2 Sampling Analyzer must be zeroed pri

Strona 3 - Equipment Description

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 11 Calibration 3.0 Introduction All analyz

Strona 4

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 12 As indicated on the certification sheet, th

Strona 5 - 1.1 Rear Panel

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 13 3.2 Sample Bag Calibration & Pressu

Strona 6 - 1.2 Right Side Panel

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 14 3.3 Calibration Procedure Analyzer must

Strona 7 - 1.3 Internal Components

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 15 General Maintenance 4.0 Battery Life B

Strona 8 - Operating Instructions

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 16 indication difficult. It is recommended

Strona 9

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 17 distilled or deionized water into the senso

Strona 10 - 2.2 Sampling

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 18 (fig. 9) Quick connect male elb

Strona 11 - Calibration

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 19

Strona 12

120-00004 REV A 10/06/2011 4000 DIGITAL MANUAL PAGE 2 TABLE OF CONTENTS SECTION TITLE

Strona 13

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 20 (fig. 12) For S-type sensors refe

Strona 14

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 21 Restore the sensor to within 5 grams

Strona 15 - General Maintenance

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 22 5.0 Troubleshooting

Strona 16 - (fig. 7)

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 23 Warranty 6.0 INTERSCAN’s Warranty Pol

Strona 17 - (fig. 8)

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 24 Return Authorization 7.0 INTERSCAN’s R

Strona 18 - (fig. 10)

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 25 8.0 Appendix Appendix A INTERFERING GAS

Strona 19 - Fig. 11

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 26 (1) Data shown for H2S models with range

Strona 20 - (fig. 12)

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 27 c. Using alternative germicides, which do

Strona 21 - 4.4 Post Storage Start-up

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 28 Chart 5: C2H4 (ethylene) analyzers [N

Strona 22 - 5.0 Troubleshooting

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 29 Appendix B SCRUBBER INFORMATION TYPE FOR A

Strona 23 - Warranty

120-00004 REV A 10/06/2011 4000 DIGITAL MANUAL PAGE 3 Introduction Note:

Strona 24 - Return Authorization

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 4 Designation Function LCD Display: Indica

Strona 25 - Appendix A

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 5 batteries power the main circuitry and

Strona 26

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 6 RECORDER OUTPUT: ¼” phone jack for Ana

Strona 27

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 7 The above (fig 3) indicated two #1 Phillips-

Strona 28 - (ethylene) analyzers

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 8 Operating Instructions For overseas shipmen

Strona 29 - Appendix B

120-00004 REV A 10/6/2011 4000 DIGITAL MANUAL PAGE 9 2.1 Zeroing the Analyzer The Analyzer m

Komentarze do niniejszej Instrukcji

Brak uwag